Veterinary Monitoring System(BW3A-V)

Veterinary Monitoring System(BW3A-V)
Product Detailed
Related Categories:Ultrasonic
1)Portable,compact Perfect Interface 2)ECG,SPO2,NIBP,TEMP,RESPERATION 3)Suitable for all Animals 4)Multi-language Option

Features:

1. Attractive streamline outline design, portable, compact and lightweight

2. 10.4" color TFT LCD display

3. Operation menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, German ……

4. Big Font Display

5. ST segment Analysis and Apnea Alarm function

6. Drug Dose Calculation and OXCRG Software

7. 72-hour tabular and graphic trends and data storage

8. High energy Li-ion battery for short-term transport and temporary power-down

9. Networking Capability. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible

10. Linux Operation System

11. External display(VGA interface) and external printer connectible to record tabular and graphic trend

12. Dynamic Monitoring of blood pressure

13. Intelligent audio and visual alarm

14. Application: Horses, Cats, Dogs or Similar Sized Animals

15. Pacemaker detection and Arrhythmia Analysis( Optional)

Technical Specs:

ECG

Input: 5 lead ECG cable

Lead section: I, II, III

Gain(mm/Mv): 1/4, 1/2, 1, 2, 4

Frequency response:

Diagnosis 0.05 - 100Hz

Monitor mode 0.5 - 40 Hz

Surgery 1.0 - 25 Hz

Sweep speed (mm/sec): 12.5, 25, 50

Heart rate range: 0-350 BPM

Heart Rate Accuracy: ±1%

Protection: Against electrosurgical interference and defibrillation

NIBP

Method: Automatic Oscillometric

Operation Modes: Manual/Automatic/Continuous

Measurement Unit: mmHg/kPa selectable

Measurement range: Systolic, Diastolic and Mean

Measurement range: 10-285mmHg

Scale: mmHg/Kpa

Accuracy: ±3mmHg or 2%(choice max)

Alarm: Systolice, Diastolic and Mean

Over-pressure Protection: Yes

Resolution: 1mmHg

SPO2

Measurement range: 0 - 100 %

Pulse Rate range: 25~400BPM

Accuracy: 70~100% ±2%(Horse & Dog)

70~100% ±3%(Cat)

0~69% Unspecified

Low Perfusion: <0.3%

Low Perfusion Accuracy: 70~100% ±2%(Horse & Dog)

70%~100% ±3%(Cat)

0%~69% Unspecified

TEMPERATURE

Alarm Range: 27~42celsius

Measurement range: 25~45celsius or 77~113fahrenheit

Accuracy: ±0.2celsius or±0.3fahrenheit

Scale: Celsius/Fahrenheit

RESP.

Method: Impedance

Measurement range: 0 - 120 BPM

Accuracy: ±1BMP or 5%(choice max)

Resolution: 1BMP

POWER REQUIREMENT

Input: 98~260 V AC, 50/60Hz

Consumption: ≤ 80VA

Safety standards:GB9706.1 IEC 60601-1 UL 544 

 

Veterinary Monitoring System(BW3A-V)